what size breaker do i need for a range hood

What Size Breaker Do I Need for a Range Hood?

Hooking up a range hood and wondering about the electrical side of things? You're in the right place. Getting the breaker size right is a crucial step that's easy to overlook in the excitement of choosing the perfect model. But don't worry, we've got your back.

We'll walk you through everything you need to know, from amps to wires, ensuring your kitchen's new addition is not only up and running but also up to code. Settle in as we shed some light on how to power your range hood just right — it's easier than you think!

Find the Perfect Range Hood for Your Kitchen: Ready to match your culinary needs with the ideal ventilation system? Explore our diverse collection of Range Hoods that cater to any cooking style and kitchen layout.

Understanding Range Hood Power Requirements

When it comes to range hood power requirements, there are a few key factors to consider. In this section, we'll discuss how to determine the amperage and wattage needed for your range hood, as well as the role of CFM in range hood performance.

Determining Amperage and Wattage

The amperage and wattage needed for your range hood will depend on its power requirements. Most range hoods require a 14/2 or a 12/2-gauge wire with ground, depending on whether they are connected to a 15 or 20-amp breaker. It is highly recommended that range hoods are connected to their own dedicated circuit. A range hood typically consumes between 65 to 300 watts of power with an average of 105 watts.

To determine the amperage needed for your range hood, you can use the following formula:

Amperage = Wattage / Voltage


For example, if your range hood requires 105 watts of power and operates at 120 volts, you would need an amperage of 0.875 amps.

The Role of CFM in Range Hood Performance

CFM, or cubic feet per minute, is a measure of the amount of air that a range hood can move in a minute. The higher the CFM, the more effective the range hood will be at removing smoke, steam, and odors from your kitchen.

When choosing a range hood, it's important to consider the size of your kitchen and the type of cooking you do. A larger kitchen or a kitchen with a high-output stove may require a range hood with a higher CFM rating.

In addition to CFM, other factors that can affect range hood performance include the size and design of the hood, the height of the hood above the cooktop, and the type of filter used.

Electrical Circuit Essentials for Range Hoods

When installing a range hood, it is essential to understand the electrical circuit requirements. In this section, we will discuss the two types of circuits that can be used for range hoods and the circuit breaker specifications.

Dedicated Circuit vs. Shared Circuits

A dedicated circuit is a circuit that is solely dedicated to powering the range hood. This means that no other appliances or devices are connected to the same circuit. According to the National Electrical Code (NEC), range hoods can be connected to a lighting circuit if certain conditions are met. The range hood must support a hardwired connection, and its rating must be less than 50% of the branch circuit rating. For instance, if you have a 15 A circuit, the range hood's rating must be 7.5 A or less.

However, it is highly recommended that range hoods be connected to their own dedicated circuit. A range hood consumes between 65 to 300 watts of power, with an average of 105 watts. Sharing a circuit with other appliances or devices may cause the circuit to overload, leading to tripped breakers or even electrical fires.

Circuit Breaker Specifications

The circuit breaker is an essential component of the electrical circuit for range hoods. It is responsible for protecting the circuit from overloading and short circuits. The circuit breaker size for a range hood depends on the circuit's amperage rating. For a 15 A circuit, a 15 A circuit breaker is required, while a 20 A circuit requires a 20 A circuit breaker.

It is important to note that the circuit breaker must match the wire size used for the circuit. For instance, a 14/2 or 12/2 gauge wire with ground is required for a 15 A or 20 A circuit, respectively. Using a smaller wire size with a larger circuit breaker can cause the wire to overheat, leading to electrical fires.

Installation and Wiring Considerations

When installing a range hood, there are a few important factors to consider. In this section, we'll cover the hardwiring vs. plug-in options and choosing the correct wire gauge.

Hardwiring vs. Plug-In Options

Range hoods can be installed using either a hardwired connection or a plug-in option. A hardwired connection involves connecting the range hood directly to your home's electrical wiring. This requires running electrical wiring from the range hood to a junction box and connecting the wires to the appropriate terminals.

On the other hand, a plug-in option involves plugging the range hood into an electrical outlet. This option is generally easier to install and doesn't require any electrical wiring. However, it's important to note that not all range hoods are designed for plug-in installation. Be sure to check the manufacturer's instructions to determine which installation option is best for your range hood.

Choosing the Correct Wire Gauge

When hardwiring your range hood, it's important to choose the correct wire gauge. The wire gauge refers to the thickness of the wire and is measured in American Wire Gauge (AWG). The correct wire gauge depends on the wattage of your range hood and the length of the electrical wiring.

For most range hoods, a 14/2 or 12/2-gauge wire with ground is sufficient. The wire gauge you choose should be able to handle the wattage of your range hood without overheating. It's also important to note that range hoods should be connected to their own dedicated circuit to prevent overloading.

Sleek and Durable Stainless Steel Vent Hoods: For a modern and robust kitchen upgrade, check out our Stainless Steel Vent Hoods. These hoods promise durability and add a touch of elegance to any cooking area.

Safety and Compliance Standards

Adherence to National Electrical Code

When installing a range hood, safety should always be a top priority. The National Electrical Code (NEC) is a set of guidelines that ensures the safe installation of electrical wiring and equipment in the United States. As a homeowner, it is your responsibility to adhere to these guidelines when installing a range hood.

The NEC 210.52 requires that all kitchen countertop receptacles be supplied by at least two 20-ampere branch circuits. This means that your range hood should have its own dedicated circuit and should not share a circuit with any other appliance or outlet in the kitchen. It is also important to ensure that the circuit breaker and wiring used for the range hood are rated for the amperage of the hood.

Grounding and GFCI Protection

Grounding is an essential safety feature in electrical installations. It provides a path for electrical current to flow safely to the ground in the event of a fault. All metal parts of the range hood, including the motor, should be grounded to prevent electric shock.

Additionally, it is recommended to install a ground-fault circuit interrupter (GFCI) to provide extra protection against electrical shock. A GFCI constantly monitors the flow of electricity and will trip the circuit if it detects a ground fault, protecting you from electric shock.

Additional Installation Considerations

Venting and Ductwork

When installing a range hood, you need to consider the venting and ductwork. A range hood can either be vented or ductless. A vented range hood requires a duct to be installed, which will allow smoke, steam, and cooking odors to be removed from your kitchen. A ductless range hood recirculates the air back into the kitchen after passing through a filter.

If you choose to install a vented range hood, you will need to make sure that the ductwork is properly installed and vented to the outside of your home. The size of the ductwork will depend on the size of your range hood, as well as the distance between the range hood and the exterior vent. It is important to use the correct size ductwork to ensure that the range hood operates efficiently.

Coordination with Other Kitchen Appliances

When installing a range hood, you also need to consider the coordination with other kitchen appliances. For example, if you have a microwave installed above your range, you will need to make sure that there is enough space between the cooktop and the bottom of the microwave for the range hood to function without getting too hot. It is also important to double-check the dimensions of your old and new range hood to ensure that it will fit properly in your kitchen.

Additionally, if you have a downdraft range hood, you will need to double-check your cabinets and countertop to ensure that there is enough space for the range hood to be installed properly.

Brighten Up with a White Range Hood: Give your kitchen a fresh, clean look with our sleek White Range Hoods. Click now to see how these stylish fixtures can lighten up your space.

Conclusion

As we've navigated the ins and outs of selecting the right size breaker for your range hood, it's clear that understanding the electrical requirements is as important as the aesthetic and functional aspects of your kitchen's ventilation. With the right breaker in place, you can cook with confidence, knowing that your range hood is powered properly for optimal performance.

If you're ready to take the next step and choose a range that matches your newfound electrical expertise, our collection of 1200 CFM Range Hoods offers the power and efficiency needed for even the most demanding kitchen environments. Discover the perfect blend of style and function to complement your culinary space and enhance your home cooking experience.


Frequently Asked Questions

What size breaker for range hood?

If you're wondering what size breaker you need for your range hood, you should know that the size will depend on the manufacturer's specifications. Generally, most range hoods require a 15-amp circuit breaker. However, it is important to check the manufacturer's instructions for the specific requirements of your range hood.

Can a range be on a 40 amp breaker?

No, a range should not be on a 40-amp breaker. Most ranges require a 50-amp circuit breaker. It is important to refer to the manufacturer's instructions for the specific requirements of your range.

What is the NEC code for range hoods?

The National Electrical Code (NEC) requires that range hoods be installed on a dedicated circuit. This means that the range hood should have its own circuit breaker and wiring, and should not be connected to any other appliances or outlets.

How many amps does a range hood fan use?

The amp rating of a range hood fan will depend on the specific model and manufacturer. Most range hood fans require between 1.5 and 5 amps. Refer to the manufacturer's instructions for the specific requirements of your range hood.

Should a range hood be hardwired or plug-in?

Range hoods can be either hardwired or plug-in. However, it is recommended that a licensed electrician hardwires range hoods to ensure proper installation and safety.

Should a range hood be on a dedicated circuit?

Yes, a range hood should be on a dedicated circuit. The NEC requires this to ensure proper electrical safety and prevent overloading of the circuit. It is important to refer to the manufacturer's instructions for the specific requirements of your range hood.

Previous article What Is the Alternative to a Vent Hood? Guide to Other Options
Next article Fridge Efficiency 101: How Many Amps Does a Refrigerator Use?

Shop By Category

View All

Shop By Brand

View All

Blog posts

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare